1# International Business Department.
0086-755-8600 0713
Mobile :+86-138 2379 0397
1F and 4F block B,Jiada R&D Bldg, High-tech Park,Nanshan,Shenzhen,China
Post code:518057
"CY-RCT02A1 (5)" Type 1 (5)A Rogowski coil split current transformer provides easy-to-install plug-and-play solution that can be connected to a power meter or a 1(5)A current transformer Equipment used in conjunction.
The Rogowski coil split current transformer Kit has a three-channel 1(5)A integrator output that can be used for most power meters and devices with 1 (5) A input. The kit offers four selectable measurement ranges including: 500A, 1kA, 2.5kA and 5kA, the detection range of 0.5% to 120% of the rated current input .Applied to 50 / 60Hz system, the rated frequency range of 45Hz to 65Hz. The mounting bracket is DIN rail or surface mount, with 24Vdc power supply.
Application :Uses: power instrumentation, electronic multi-function energy meter and field calibrator, instrumentation measurement and protection.
Features:
No need to disconnect the bus line power outage, easy installation.
Simple and quick installation in a small space;
Fine design, coil size can be customized
Excellent linearity;
Dimension and wire schematic:
Model code:
Technical data:
No. |
Technical data |
data |
Note |
|
Range of current measurement |
0.5 - 5000 A |
(80 dBSignal range) |
|
Output |
0 - 5 A(RMS) |
|
|
Variable range stalls |
500A,1kA,2.5kA,5kA |
(selectable ) |
|
Max burden |
1.25 VA each channel |
|
|
Max output impedance |
50 mΩ |
|
|
Measuring channel |
Single / three phase |
|
|
frequency |
50/60 Hz |
|
|
Ratio error |
±1% |
|
|
Phrase error |
< 1.5 ° @ 50Hz |
|
|
Linearity |
±0.3% (5% - 120%In) |
|
|
Position sensitivity |
±2% |
|
|
Field effect |
±1% Range (distance coil)>200mm) |
|
|
environment |
Indoor |
|
|
Power requirements |
voltage:48VDC ±10%,30w |
|
current:0.6安培 DC @ 48VDC |
|
||
|
Cable length |
2m(Measuring head to electronic module) |
|
|
output/input connection |
18 - 28 AWG / 12 - 18 AWG |
|
|
Operating temperature |
-20℃-40℃ |
|
|
Relative humidity |
5%〜95%no Condensation |
|
|
Accessories |
TS35/7 DIN installation trail |
|
Note :All precision is specified at 20 ° C and the coil is centered on the conductor. Typical accuracy of the coil <1%。
Dimension and schematic:
The match coil can be our “CY-RCT01”or“CY-RCT02” series, or customized also.
Function and Application :
Function :General measurement and protection in power systems for highly mobile or space-constrained or uninterrupted power systems.
Application :Uses: power instrumentation, electronic multi-function energy meter and field calibrator, instrumentation measurement and protection.
Attention:
When flexible rogowski coil measurement probe connected, the cable under test should be placed in the middle of the flexible rogowski coil and the coil can be kept vertical to effectively reduce the measurement error.
in daily use , please ensure the correct connection of the XS1 terminal's positive and negative polarity of the power supply, once incorrect connection, the inside chip will be damaged.
If the output channel for more than 5 amps RMS may cause RōCoilTCA-5 to overheat and damage.
1# International Business Department.
0086-755-8600 0713
Mobile :+86-138 2379 0397
1F and 4F block B,Jiada R&D Bldg, High-tech Park,Nanshan,Shenzhen,China
Post code:518057