Features:
.Flexible and light weights,exquisite appearance
.Easy &quick installation in tight spaces
.Excellent linearity
.Maximum measuring current up to 130A
Applications:
.Power quality monitoring .CT secondary current detection .Smart logger .Distributed measurement systems
The “RCTA03 lamp Clamp-on Flexible Rogowski coil current transformer “is dsigned for easy installed in tight spaces and without the need for dismantling the primary busbar or cables .It includes a flexible Rogowski coil probe and electronic modules. The signal from the coil probe can be amplified by the electronic codules through the integration processing . The output signal can be directly used in oscilloscope,digital multimeter or data logger recording instrument
Model:
General data:
.Operating temperature&humidity:0 to 50ºC(32-122ºF), ≦80% RH(No condensate)
.Storage temperature&humidity:-10 to60ºC(14-140ºF), ≦80% RH(No condensate)
.Operating environgment:Indoor ,altitude up to 2000 meters
.Standard safety: IEC61010-1:2001,600V CATⅢ
Dimension:
Eletrical Parameter:
The test environment for the accuracy:23±5 ºC), ≦85%RH
Model
Data |
CY-RCTA03-305 |
Current Range |
60A/600A/6000A(10%-100%In) |
Output Sensitivity |
500m V/A,5m V/A, 0.5m V/A |
Accuracy |
±1%(10%-100% In)@45-65Hz |
Phase error |
±1%(10%-100% In)@45-65Hz ±10º@20kHz |
Linearity error |
±0.2%(10%-100% In) |
Position Sensitivity |
±0.2%(The distance from the measured cable to junction is above 20mm |
External Influence |
±1%Max (more than 200mm from the coil) |
Noise |
8m V rms (60A) |
Temperature Coefficient |
2m V rms(60A) |
Frequency Range |
±0.08% Cof the reading data |
Power |
Min 100KΩ |
Power |
2*AA/MN1500/LR6 Battery(400hrs) Eternal Adapter:4.5V DC |
Power LED indicator |
ON indication When normal power (Red light goes off after 3 seconds ) low battery indication(Red is always on) |
Overload LED indicator |
Overload above 120% of the range indication(yellow)
|
Operating Voltage |
600V AC RMS or DC |
Security Level |
IEC 61010-1:2001,600V CAT Ⅲ) |
Cable length |
3m(Measuring head to the electronics module ) |
Output terminals |
0.5m cable with safety BNC plug |
Weight |
230g(measuring head),130g(Electronic modules) |